. EXHAUST EMISSION CONTROL
SYSTEM
SECONDARY AIR CLEANER / AIR
INJECTION CUT-OFF VALVE (A.I.C.V.)
REMOVAL
Remove the seat. ( Ö 2-4)
Remove the body cover.
Disconnect the secondary air cleaner
/(A.I.C.V) connecting tube.
INSPECTION
Inspect the air injection cut-off valve flow
using a vacuum pump. If the flow is not
within the specified values, replace with a
new one.
The flow should be at least 30 liter/min
when a vacuum of 250mm/Hg is applied.
The flow should be at least 1.6 liter/min
when a vacuum of 320mm/Hg is applied.
Check each connecting tube for cracks or
damage and replace if necessary.
INSTALLATION
The installation sequence is the reverse of
removal.
x The secondary air cleaner must be
assembled and installed properly to
avoid dust entering the air cleaner.
x When installing, be careful not to
bend or twist the tubes and check for
proper installation.
x The tube length is very important to
its performance, use the tube of
same specification for replacement.