KYMCO People Service Manual page 145

Hide thumbs Also See for People:
Table of Contents

Advertisement

12. COOLING SYSTEM
SPECIFICATIONS
Radiator cap relief pressure
Thermostat temperature
Coolant capacity
COOLANT GRAVITY
Temp.
Coolant
0
concentration
5%
1.009 1.009 1.008 1.008 1.007 1.006 1.005 1.003 1.001 0.009 0.997
10%
1.018 1.107 1.017 1.016 1.015 1.014 0.013 1.011 1.009 1.007 1.005
15%
1.028 1.027 1.026 1.025 1.024 1.022 1.020 1.018 1.016 1.014 1.012
20%
1.036 1.035 1.034 1.033 1.031 1.029 1.027 1.025 1.023 1.021 1.019
25%
1.045 1.044 1.043 1.042 1.040 1.038 1.036 1.034 1.031 1.028 1.025
30%
1.053 1.051 1.051 1.049 1.047 1.045 1.043 1.041 1.038 1.035 1.032
35%
1.063 1.062 1.060 1.058 1.056 1.054 1.052 1.049 1.046 1.043 1.040
40%
1.072 1.070 1.068 1.066 1.064 1.062 1.059 1.056 1.053 1.050 1.047
45%
1.080 1.078 1.076 1.074 1.072 1.069 1.056 1.063 1.062 1.057 1.054
50%
1.086 1.084 1.082 1.080 1.077 1.074 1.071 1.068 1.065 1.062 1.059
55%
1.095 1.093 1.091 1.088 1.085 1.082 1.079 1.076 1.073 1.070 1.067
60%
1.100 1.098 1.095 1.092 1.089 1.086 1.083 1.080 1.077 1.074 1.071
COOLANT MIXTURE (WITH ANTI-RUST AND ANTI-FREEZING EFFECTS)
Freezing Point
-9
-15
-25
-37
-44.5
Cautions for Using Coolant:
x Use coolant of specified mixing rate. (The
mixing rate of 425cc KYMCO SIGMA
coolant concentrate + 975cc distilled
water is 30%.)
x Do not mix coolant concentrate of
different brands.
x Do not drink the coolant which is
poisonous.
x The freezing point of coolant mixture shall
be 5 lower than the freezing point of the
riding area.
12-3
Begins to open
Full-open
Valve lift
Total system 1400±20cc
5
10
15
Mixing Rate
KYMCO SIGMA Coolant Concentrate
20%
30%
40%
50%
55%
0.9r0.15kg/cm²
80r2
90
3.5 4.5mm
Radiator: 1000±20cc
Reserve tank: 400±20cc
20
25
30
35
425cc
PEOPLE/PEOPLE S 250
40
45
50
Distilled Water
975cc

Advertisement

Table of Contents
loading