EPSON AcuLaser C4000/C4100/C3000
4.2.12 FUSER ASSY & BTR ASSY
4.2.12.1 FUSER ASSY (PL9.1.1) Removal
The FUSER is very hot, so to avoid burns use great caution
W A R N I N G
when it is operating.
1. Release the latch A and open the CHUTE ASSY IN (PL7.1.1).
2. Open the COVER ASSY TOP PHD (PL1.1.15) from the printer body.
3. Close the CHUTE ASSY IN.
4. Release the latch B of the printer body and open the CHUTE ASSY OUT
(PL7.1.1).
5. Release the 2 lock of right and left side on the FUSER ASSY upper side.
6. Remove the FUSER ASSY from the printer body.
Disassembly and Assembly
Disassembly Assembly Procedures
Figure 4-78. FUSER ASSY (PL9.1.1) Removal
Revision F
D
4-381