T-1 Ordering Information - Vodavi XTS-IP Installation Manual

Hide thumbs Also See for XTS-IP:
Table of Contents

Advertisement

3-30
Chapter 3 - System Installation
LED #
1
2
3
4
5
6
7
8
The T1IB contains 2 switches (SW1 and SW3) and 3 connectors (CN1, CN2 and CN3). The clock
selection switch is used for control synchronous clock. The Line Build-Out switch is controlled
by distance between the XTS-IP Systems and a CSU and SW1 #4 is used for loopback control.
The clock control cable should be connected by a daisy-chain method when more than one
T1IB board is installed. When the clock control cable of the T1IB is connected by daisy-chain
method, the clock selection switch of the first T1IB must be placed in the Enable position and
the other board should be placed in the Disable position. The Line Build-Out switch must be
selected by distance between the XTS-IP System and a CSU and the switch selection as
indicated in the following chart. If the CSU is located near the KSU, all LBO switches should be
ON.
The SW1 switch #4 of the Line Build-Out switch is used for loopback control. Its switch is used
only for hardware test and must be placed in the ON position for normal operation.
Ringer Equivalent Number
Facility Line Interface
Jack Type
XTS-IP - Installation Manual
Table 3-5: T-1 Board LEDs
Meaning
IN USE
At least one of the 24 circuits is in use.
RED
T1IB is in Red alarm due to any alarm.
H/W TEST
Normal call processing is not available.
BLUE.
T1IB has detected RX_BLUE alarm.
YELLOW
T1IB has detected RX_YELLOW alarm.
OOF
T1IB is Out of Frame synchronization.
RCL
T1IB receives Carrier Loss (unplugged from the cable)
CLOCK
Clock Enable/Disable
Table 3-6: T-1 Ordering Information

T-1 Ordering Information

Table 3-7: T-1 Switch Positions
Distance
0 to 133 feet
133 to 266 feet
266 to 399 feet
399 to 533 feet
Function
Switch #
1
2
on
on
on
off
on
on
on
off
on
off
off
on
CO/PBX Connections
6.0P
04DU9-B
RJ45
3
4
on
on
on
on
December 2005

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents