Chapter 4 - Maintenance and Troubleshooting

Flash ROM Software Update

Save/Download your KSU database (refer to "Database UPload/Download Routine" in
Appendix F of the Programming and Operations Manual), then perform the following steps to
update Flash ROM Software.
1. Connect a terminal to I/O Port 1 on the MPB, then press <Enter> several times until the
following system data displays:
300 Digital Hybrid Key System
Eng. V1.00 P0X-FFFF DATE:MM/DD/YY TIME: 11:10:27
ENTER PASSWORD:
2. At the ENTER PASSWORD: prompt, type config.
3. Press <Enter>, the following maint> prompt will display:
maint>
4. Type u to select "upload/download flash rom software" option, then press <Enter>. The
following will display:
Enter password>
5. Type the remote admin password (3226vodavi = default password), then press <Enter>.
The following command options and system prompt will display:
COMMAND DESCRIPTION
____________________
b
s
u
x
? or h
maint>swupdown>
XTS-IP - Installation Manual
The password characters will not display on the screen as the password is
being typed.
show baud rate
bank switching
upload software using zmodem
Exit
Help, Guide
Flash ROM Software Update
December 2005