System Configuration Tables
Stations
Analog Stations
Digital Telephones
Single Line Telephones
UCD Groups
Groups
Members
RAN Announcements
Calls In Queue
Voice Mail Groups
Groups
Members (ports)
Integration Method
Positive Disconnect
VM Message Wait
VM Disconnect Signal
Operation Temperature
Optimum Operation Temperature
Storage Temperature
Relative Humidity
Item
Analog Electronic Telephone*
Digital Telephones*
Single Line Telephones*
*All stations must be installed in the same building. Station circuitry does not contain protection to support off-
premise operation.
For a Key System configuration (button appearance)
For a Hybrid System configuration (dial access codes)
XTS-IP - Installation Manual
Table 2-3: System Capacity
MPB1
96 maximum
Software supports up to 8 Groups
Software supports up to 8 stations in each Group
32 RAN Announcements per system, 2 per UCD Group
All CO Lines may be queued for a UCD Group
Software supports up to 8 Groups
Software supports up to 24 stations per group
In-Band signaling (DTMF)
Loop supervision is provided to ensure disconnect
Programmable 12-digit (DTMF) string
If 0 digits are programmed, 15 sec of silence are followed by a busy tone.
Table 2-4: Environment Specification
Item
Table 2-5: Loop Limits
Maximum length of station loop:
1000 feet of 24 AWG
(4 wire, inside wiring, twisted cable)
Maximum length of station loop:
1000 feet of 24 AWG
(2-wire, inside wiring, twisted cable)
2000 feet of 24 AWG
Table 2-6: FCC Registration Numbers
System
Chapter 2 - System Specifications
MPB2
252 maximum
(No more than 96
stations are supported
per Cabinet.)
Degrees (ºF)
32-104
68-78
32-158
0-80% non-condensing
Capacity
KF: 5JYKOR-45504-KF-E
MF: 5JYKOR-45505-MF-E
MPBE
400 maximum
400 maximum
480 maximum
Degrees (ºC)
0-40
20-26
10-70
FCC Number
December 2005
2-7