Chapter 4 - Maintenance and Troubleshooting
Ping followed by an IP address receives the following response:
root:\p xxx.xxx.xxx.xxx
Reply from xxx.xxx.xxx.xxx: bytes 32 time=xxms
Reply from xxx.xxx.xxx.xxx: bytes 32 time=xxms
Reply from xxx.xxx.xxx.xxx: bytes 32 time=xxms
Reply from xxx.xxx.xxx.xxx: bytes 32 time<xxms
Reply from xxx.xxx.xxx.xxx: bytes 32 time=xxms
(A "reply from" response indicates that the system can communicate with the other
system. A "timed out" response indicates a faulty connection or problem with the other
system.)
LAN Firmware Upload Mode - From the main menu, type [u] (to select LAN Firmware Upload
Mode) and press <Enter>.
1. Type [c] (to select change baud rate).
2. Type [4] to select 57600 bps, then press <Enter>.
3. Reconfigure HyperTerminal to the new baud rate.
4. Type [y] to confirm the change to 57600 bps.
5. Type [?] to redisplay the LAN Software Upload Mode menu.
6. Type [u] (to select sw upload with Zmodem) and press <Enter>.
7. Type [y] and press <Enter> to begin upload.
8. Click Transfer/Send File.
9. Navigate to and select the correct upload file for the upgrade.
10. Select the Zmodem protocol and click Send.
11. When "Starting Flash Upgrade!" appears, type [y] and press <Enter>.
The VoIP card accepts the upload.
When the upload is complete, the VoIP card is reset.
All VoIP COs are automatically placed back in service.
12. Change the baud rate to 9600 bps using HyperTerminal or other terminal emulation
application (disconnect, change the baud rate, re-connect). To change the baud rate,
choose the Upload menu again and then select the option to change the baud rate.
Follow the instructions on the screen.
XTS-IP - Installation Manual
All COs on that card will be out of service.
VoIP Maintenance and Troubleshooting
December 2005