Chapter 4 - Maintenance and Troubleshooting
9. Type y to switch the banks of Flash ROM now, or type n if you wish to switch at a later
time. If "y" is selected, the following messages will display:
Bank 0 has valid software key...
Bank 1 has valid software key...
Please, wait until bank switching is finished and
system is reset automatically...
After reset, banks would be switched as requested...
Please maintain power during the process. Please wait..
After the software is switched successfully, the XTS-IP system will restart automatically.
10. To use the newly loaded software, place switch 8 to the on position (to default KSU
database). Power the XTS-IP system Off or On, whichever applies. When the system is up,
place switch 8 to the off position and upload the database (refer to "Database UPload/
Download Routine" in Appendix F of the Programming and Operations Manual). After the
upload, cycle KSU power.
To switch to the new software at a later time:
1. Connect a terminal to I/O Port 1 on the MPB. The following is an example of the data that
will display:
300 Digital Hybrid Key System
Eng. V1.00 P01-FFFF DATE:MM/DD/YY TIME: 11:10:27
ENTER PASSWORD:
2. Type the password config and press <Enter>. The following prompt will display:
maint>
3. Type u to select the "upload/download flash rom software" option. The following
password prompt will display:
Enter password>
4. Type the remote admin password (3226vodavi = default password), then press <Enter>.
XTS-IP - Installation Manual
The password characters will not display on the screen as the password is
being typed.
Flash ROM Software Update
December 2005