FUEL SYSTEM
AIR CLEANER HOUSING
REMOVAL
Remove the fuel tank (page 3-4).
Remove the throttle stop screw knob from the air
cleaner housing stay.
Remove the air cleaner housing mounting bolts and
collars.
Disconnect the crankcase breather hose from the air . . - - - - ­
cleaner housing.
Loosen the air cleaner housing connecting tube
band screw.
Remove the air cleaner housing.
DISASSEMBLY
I
ASSEMBLY
1.1 N'm (0.1 kgf'm, 0.8IbHt)
AIR CLEANER CHAMBER
0.7 N'm (0.1 kgf·m, 0.5 IbHtl
AIR CLEANER CHAMBER
CONNECTING TUBE
1.5 N'm (0.2 kgf'm, 1.1 IbHt)
a-RING
COVER
6-6.