8. Vector Chart Material
ENC to SENC conversion fails or detects errors
If the SENC conversions detect
anything abnormal, you get
following message window:
For further details, see paragraph 8.4
"S57 SENC Conversion Details".
A new edition of the chart has been published and you missed it
If you tried to load updates for a
chart for which you do not have new
enough Base cell or reissue in your
hard disk, you will get following
message:
The message above clearly indicates that this chart is not up-to-date and thus it does not fulfil SOLAS requirements.
Get the latest edition of the chart from the publisher immediately.
You do not have all the published updates
If you tried to load updates and you
missed one or more updates between
updates already loaded into your
hard disk and the updates that you
are loading, then you get following
message:
The message above indicates that you tried to load update numbers 3, 4 and 5 when at least update 2 and possibly
update 1 were not available in your hard disk. Check the content of your CD ROMs to find the missing
update/updates or contact your chart supplier.
The message above clearly indicates that this chart is not up-to-date and thus it does not fulfil SOLAS requirements.
Get the latest edition of the chart from the publisher immediately.
Unsafe chart has been cancelled by the publisher
If you load an update which contains
instructions from the publisher to
cancel the chart, you get following
message:
Normally, you should accept the cancellation by clicking the Yes button. Then the system automatically removes the
chart from the hard disk and from your chart screen.
You may elect to keep the chart although the publisher of it has told you that the content of the chart is so unsafe
that they have cancelled it. The reason might be that you do not have anything better available. In this case, click the
No button. Then the system automatically removes the ENC status from the chart, because the publisher has told so
in his special cancellation update.
Note that the cancellation message above clearly indicates that the publisher says that this chart is unsafe for
navigation and thus it does not fulfil SOLAS requirements. Get the latest edition of the chart from the publisher
immediately to replace the unsafe cancelled chart.