Furuno FEA-2107 Operator's Manual page 637

Electronic chart display and information system (ecdis)
Hide thumbs Also See for FEA-2107:
Table of Contents

Advertisement

Appendix 8: Digital Interface
A8.1 Data Sentences
A8.1.1
Input sentences
DBT, DPT, DTM, GGA, GLL, HDT, MTW, MWV, OSD, ROT, RSA, TTM, VBW, VDM, VTG, ZDA,
A8.1.2
Output sentences
DTM, GLL, MWV, RTE, WPT
A8.1.3
Data reception
Data is received in serial asynchronous form in accordance with the standard referenced in
IEC 61162-2.
The following parameters are used:
Baud rate: 38,400 bps: HDT, !AIVDM, !AIVDO and $AIALR. All other sentences: 4800 bps
Data bits: 8 (D7 = 0), Parity: none, Stop bits: 1
D0
D1
Start
bit
D2
D3
D4
D5
Data bits
D6
D7
Stop
bit
AP-85

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fea-2107-bbFea-2807

Table of Contents