4630 and 4830 Bar Code Label Printers User's Manual

Human-Readable Field, Create/Edit

Use this command to edit or create a human-readable field n.
Purpose:
Syntax:
H n [, name ]
n values can range between 0 and 199.
,name is an optional field. The field can be up to eight ASCII characters (not
counting the semicolon) and cannot start with a numeric character.
Default:
n = 0
Notes:
If n does not exist, a default human-readable field is created.
Parameters for the default field:
Border = disabled
Character rotation = 0°
Data length = 30
Data origin = Print mode
Field direction = 0°
Field origin = 0,0
Font = 7x9 standard
Height magnification = 2
Pitch = disabled
Point = disabled
Width magnification = 2

Intercharacter Space for UDF, Define

Purpose:
Defines the intercharacter gap length for a user-defined bitmap font in dot
increments.
Syntax:
z n
n values can range between 0 and 199.
Default:
n = 2
Notes:
An error code (52) is generated for invalid lengths.