Field Data, Define Source

Purpose:
Defines a data source for the current field and how many characters are in the
field.
Syntax:
d n [, m1 ][, m2 ];
n can range from 1 to 3.
,m1 is the number of characters that can be entered into the field and can range
from 1 to 200.
,m2 is an optional positive integer numeric field offset that can range from 0 to
9999.
Default:
n = 0 or 1, ,m1 = 20
n = 0 or 1, ,m1 = 30
n = 2, ,m2 = 0
Notes:
d0[, m1 ] and d1[, m1 ];
Optional data is entered in Print mode. m1 is the maximum number of data (up
to 200 characters) that can be entered into this field.
d2,[ m1 ][, m2 ];
Data is copied to this field from field m1. You must define field m1 before you
can use this command. Only data delimited by numeric field separator (FS), or
alphanumeric field separator (GS), can use the offset. A bar code field cannot
copy data from a human readable field but a human readable field can copy
data from a bar code field.
d3,[ m1 ];
Fixed data m1 is stored as part of the format and is used every time the current
field is printed. The maximum number of characters in a field (including non-
printing characters) is 200. Data entered cannot be changed by print
commands.

Field Direction, Define

Purpose:
Defines the field rotation.
Syntax:
f n
n = 0
n = 1
n = 2
n = 3
n = 0
Default:
Bar code fields
Human-readable fields
Horizontal
Rotated 90 degrees counterclockwise from horizontal.
Rotated 180 degrees counterclockwise from horizontal.
Rotated 270 degrees counterclockwise from horizontal.