FO3 - 48hrs (2 days): This option will allow the antenna to power down 48hrs after being armed.
Note: once the antenna has powered down, 1 Way operation to the vehicle will stop. 2 Way operation
will still function incase any alerts are sent to the remote. In order to wake up the antenna the user
must unlock/disarm using a Firstech accessory, power ignition or trigger the alarm.
FO4 - 72hrs (3 days): This option will allow the antenna to power down 72hrs after being armed.
Note: once the antenna has powered down, 1 Way operation to the vehicle will stop. 2 Way operation
will still function incase any alerts are sent to the remote. In order to wake up the antenna the user
must unlock/disarm using a Firstech accessory, power ignition or trigger the alarm.
4-14 Low battery: This feature offers low battery options to help alert the user of a low battery in the
vehicle.
FO1 - Off: (default) This option does not provide a low battery indication.
FO2 - On: This option will provide an alert to any Firstech 2 Way LCD remote or Drone when the
vehicle's battery voltage (at the CM7 power connector) drops to 11.7volts. Note: the Firstech 2
way LCD remote must be within range of the vehicle to receive the low battery alert
and this option must be set in order to receive low battery alerts to Drone.
FO3 - On + Start: This option will provide an alert to any Firstech 2 Way LCD remote or Drone
when the vehicles battery voltage (at the CM7 power connector) drops to 11.7volts. In addition to
the alert the user can active the Timer mode (please refer to this manual for timer mode feature
description) to enable the low battery start function. Once the timer mode is active the CM7 will
adhere to the timer mode feature options selected but also monitor the vehicle battery voltage which
will override the timer mode and start at 11.7 volts.
Special Option Groups 1 & 2
IMPORTANT: The OP500 is required to change settings in Special Option Groups 1 and 2.
Special Option Group 1
FO1- Diesel Timer: (Option 2-03 must first be set to setting 2.) This special option allows a
specific wait to start time (in seconds) to be programmed. This prevents the need for a timer relay and
eliminates a connection to the "wait to start" wire.
FO2 - Aux 1 Output Timing: (Option 4-01 must first be set to setting 4.) This special option
allows a specific output duration for Aux 1 to be programmed 1-99 seconds. Note with OP500
update, latched output time 1-15 minutes are available for programming in addition
to the standard 1-99 seconds.
FO3 - Aux 2 Output Timing: (Option 4-02 must first be set to setting 4.) This special option
allows a specific output duration for Aux 2 to be programmed 1-99 seconds. Note with OP500
update, latched output time 1-15 minutes are available for programming in addition
to the standard 1-99 seconds.
FO4 - FO8- Aux 3-7 Output Timing: (Option 3-11 must first be set to setting 2 and the optional
Auxiliary settings module must be used and AUX 3-7 function only available with 2 Way LCD remotes)
These special options allow specific output durations to be set for Aux 3-7. Note with OP500
update, latched output time 1-15 minutes are available for programming in addition
to the standard 1-99 seconds.
Special Option Group 2