Firstech CM7000 Master Manual page 44

Alarm and starter
Hide thumbs Also See for CM7000:
Table of Contents

Advertisement

CM7000 Master Guide
FO2 - Full alarm: This option will allow the AUX sensor input 1 to activate the full alarm cycle on
the CM7 when triggered with negative input. (I.e. additional proximity, glass break, or impact sensor
full alarm trigger)
FO3 - CM7 Disarm: this option will allow the AUX sensor input 1 to disarm the CM7 when
triggered with a (-) negative trigger.
FO4 - Open Circuit: this input will allow the AUX sensor input 1 to trigger the full alarm with an
open circuit trigger (ground removed from the input). Note: this input will NOT work for reservation
mode set up or act as door trigger input. When triggered the 2 way LCD remote will show "shock"
and Drone will push a "theft alert triggered" message.
4-07 AUX input 2 (-): (green AUX sensor connector input pin 2) this feature will determine the operation
of the AUX input 1 on the green input connector.
FO1 - Full alarm: This option will allow the AUX sensor input 1 to activate the full alarm cycle on
the CM7 when triggered with negative input. (I.e. additional proximity, glass break, or impact sensor
full alarm trigger)
FO2 - Pre-Warn: This option will allow AUX sensor input 1 to activate the pre-warn cycle on the
CM7 when triggered with negative input. (I.e. additional proximity or impact sensor pre-warn trigger)
FO3 - CM7 Arm: this option will allow the AUX sensor input to arm the CM7 when triggered with a
(-) negative trigger.
FO4 - Open Circuit: this input will allow the AUX sensor input 1 to trigger the full alarm with an
open circuit trigger (ground removed from the input). Note: this input will NOT work for reservation
mode set up or act as door trigger input. When triggered the 2 way LCD remote will show "shock"
and Drone will push a "theft alert triggered" message.
4-08 FAD with Aux 1 and Aux 2: this feature will provide an Unlock or Factory Alarm Disarm (FAD)
output when triggering the AUX control using iDatalink Modules (Sliding Doors)
FO1 - Off: (default) This option does not provide an unlock or a FAD output when activating AUX
output control using the iDatalink modules.
FO2 - Unlock and FAD: This option will provide unlock and a FAD output when activating AUX
output control using iDatalink modules.
FO3 - FAD only: This option will only provide a FAD (factory alarm disarm) output when activating
AUX output control using iDatalink modules.
4-09 PIC 3 (-): (Programmable Input Channel 3 CN5 Pin 1 brown/white) this feature will determine the
input function of PIC 3.
FO1 - Keysense: (default) INPUT only this option will allow PIC to read negative input as a
Keysense input. This is recommended for manual transmission vehicles, EZGO systems, and when
using passive arming. This prevents any action by the CM7 until (-) negative is removed from the
input.
FO2 - Glow plug: This option will allow PIC to read any negative input as a glow plug or wait to
start input. This is recommended for diesel vehicles that may have a negative analog glow plug output
available.