Firstech CM7000 Master Manual page 26

Alarm and starter
Hide thumbs Also See for CM7000:
Table of Contents

Advertisement

CM7000 Master Guide
Feature
Tach Sensing Method
2-01
Turbo Timer
2-02
Diesel Timer
2-03
Trigger Start
2-04
Cold or Hot Start with Therm-
2-05
istor Assembly
Timer Start, or, Minimum
2-06
Interval Between Cold Starts
Remote Start Runtime
2-07
Temperature of Cold Starting
2-08
Temperature of Hot Starting
2-09
Engine Sensing
2-10
Advanced Tachless
2-11
Crank Time
2-12
Timer Mode
2-13
Emergency Brake or Parking
2-14
Light Reminder Input
Feature
Parking lights While Remote
3-01
Started
Confirmation Chirps
3-02
Dome Light Delay
3-03
Starter-Kill Relay
3-04
Anti-Jacking
3-05
Factory Alarm Option
3-06
Siren Duration
3-07
(Upon Alarm Trigger)
Horn Output
3-08
Siren Output
3-09
Copyright 2014 Firstech, LLC.
Option Group 2
Default Setting - I
Optional Setting - II
Optimal Tach Method
Previous Tach Method
Off
Wire
Off
Off
3 Hour (4 minute
1.5 Hour(4 minute
runtime, double for
runtime, double for
Diesel)
15 Min
-10° C / 14° F
25° C / 77° F
Tach
Off
Standard
Off
(-) Emergency Brake
Input
Option Group 3
Default Setting - I
Optional Setting - II
Constant Output
Medium (30 ms)
Off
Anti-Grind + Starter
Kill
Starter-kill
(No Anti-Grind)
On
30 sec
On Double Lock Only
On Lock and Unlock
On Lock, Unlock, and
On Double Lock Only
Start
Alarm and Starter System
Optional Setting - III Optional Setting - IV
2 Min
3~99sec
(12 sec Default)
Single Pulse
Cold Start Only
Hot Start Only
Reservation (Runtime
set by 2-7) 2 Way LCD
Diesel)
Remotes Only
25 Min
-20° C / -4° F
-5° C / 23° F
30° C / 86° F
35° C / 95° F
No Connection -
Alternator
Tachless Sensing
(Automatic Trans Only)
On
+0.2 Seconds to
+0.6 Seconds to
Crank Time
On
(-) Trigger Start
(-) Parking Light
Reminder Input
Optional Setting - III Optional Setting - IV
Flashing Output
Short (15 ms)
Normal (60 ms)
5 sec
Anti-Grind + Passive
Anti-Grind
Ignition-Kill
Off
60 sec
On Lock, Unlock, and
On Lock and Unlock
techfeed.compustar.com
1Min
7 sec
GM Ignition Delay
Double Pulse
Triple Pulse
Cold and Hot Start
24 Hour Repeat with
Cold Starting of 2-8
(Runtime set by 2-7) 2
Way LCD Only
45 Min
-15° C / 5° F
40° C / 104° F
No Connection – 3
Second Crank
(Automatic Trans Only)
(-)0.2 Second Crank
Crank Time
Input
Off
45 sec
Starter Kill
120 sec
Chirps for 20 seconds
On Double Lock and
Start
On Double Lock and
4 Min
3 Min
Time
Auto
Start
Start
Page 26

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents