Setting Auxiliary Outputs On Connector 2 - Firstech CM7000 Master Manual

Alarm and starter
Hide thumbs Also See for CM7000:
Table of Contents

Advertisement

CM7000 Master Guide
Jumper 2 (2nd Ignition / 2nd Starter / 2nd Parking light)
Jumper 2 sets the behavior of the large blue wire on Connector 1. This wire is powered by an internal relay
in the control module. In the default position the jumper is set to 2nd Ignition. 2nd Ignition is common on
GM and Toyota vehicles and will need to be powered. You can change the behavior of the wire to act as a
2nd Starter or 2nd Parking light to power up those wires common on newer Toyotas and Nissans.
Jumper 3 (Parking Light, 2nd Starter, or (+) Trunk Release)
Determines the output (not polarity) of the green/white wire on connector one (CN1). In the default position
it provides a positive (+) parking light output. Additional jumper settings (including Positive (+) 2nd Starter,
or positive (+) trunk output) can be selected by moving the jumper positions.
Jumper 4 (Accessory, 2nd Ignition, 2nd Starter)
This Jumper offers additional high current output options using the default Accessory wire on connector one
(CN1 white wire). When selected, this wire provides additional positive (+) Ignition or Starter output instead
of Accessory.

Setting Auxiliary Outputs on Connector 2

You Must Have the OP500 Option Programmer
Setting auxiliary outputs on the control module involves the Programmable Output Connector wires (POCs).
Choose two odd pin wires that you are not using on the grey 20 pin connector. For example we will use
POC 7 and 8.
STEP 1: Plug in OP500 and use the Right or Left Arrow Button to scroll through the menu to POC 7 and
POC 8 on LCD Line 1.
STEP 2: Use the Up or Down Arrow Button to change the lower number on LCD Line 2 to 10 – Auxiliary
1 or 11- Auxiliary 2.
STEP 3: Scroll up the menu to Option 4-01 and 4-02 and set the options. Please see the Option Table
for details.
STEP 4: Our control modules have a secure auxiliary option 4-05. This requires you to tap the Start
Button before you tap the Trunk Button for Aux 1 or Hold Trunk + Start for 2.5 an then tap
Trunk for Aux 2. On 1-Way remotes you must hold the Trunk and Start Buttons for 2.5 seconds
then tap the Trunk Button for Aux 1 or the Start Button for Aux 2.
STEP 5: If you need to change the time settings of the outputs, scroll down to AU1 or AU2 on the
OP500. LCD Line 2 is the timed output. Note: with an OP500 update (techfeed.
compustar.com) you will now be able to allow for timed AUX outputs of up to
15 minutes.
STEP 6: Hold the "W" Write button for 3 seconds to set all the options.