Firstech CM7000 Master Manual page 33

Alarm and starter
Hide thumbs Also See for CM7000:
Table of Contents

Advertisement

CM7000 Master Guide
2-01 Tach Sensing Method: This feature will determine the point at which the CM7 releases the starter
based on the sampled tach method.
FO1 - Optimal Tach reading: This option will allow the CM7 to sample the tach signal several
times during tach programming and select the optimal tach voltage at which to release the starter.
FO2 - Previous tach reading: This option will set the CM7 to record the idle voltage which it is
being programmed. The CM7 will release the starter once the idle tach voltage is met.
2-02 Turbo Mode: (This feature requires door and e-brake input) This feature allows the user to
activate Turbo Timer Mode with their Firstech remote or accessory. This will keep the engine running
after removing the key for the specified time selected below. (Please check specific remote or
accessory user's manual for steps to activate Turbo Timer Mode)
FO1 - Off: (default)
FO2 - 2 Minutes: This option allows for a 2 minute run time after Turbo Mode has been engaged.
To engage, set the e-brake, remove key, exit vehicle, and lock with the Firstech remote or accessory.
Note: when using Turbo Mode with a manual transmission, the CM7 will not lock the
doors automatically. Before the turbo timer expires, the system must be locked using
the Firstech remote or accessory.
FO3 - 1 minute: This option allows for a 1 minute run time after Turbo Mode has been engaged.
To engage, set the e-brake, remove key, exit vehicle, and lock with the Firstech remote or accessory.
Note: when using Turbo Mode with a manual transmission, the CM7 will not lock the
doors automatically. Before the turbo timer expires, the system must be locked using
the Firstech remote or accessory.
FO4 - 4 minutes: This option allows for a 4 minute run time after Turbo Mode has been engaged.
To engage, set the e-brake, remove key, exit vehicle, and lock with the Firstech remote or accessory.
Note: when using Turbo Mode with a manual transmission, the CM7 will not lock the
doors automatically. Before the turbo timer expires, the system must be locked using
the Firstech remote or accessory.
2-03 Diesel Timer: Note: OP500 required to adjust time from any of the default settings,
will show up as DISL on the top line of text when option 2 or 3 are enabled. This feature
provides a timed alternative solution to a hard wired glow plug input to enable the CM7 to wait to
start.
FO1 - Wire: (default) This option will allow the CM7 to read input on brown/white wire. (PIC3) It
may be connected to a wait to start indicator on a diesel vehicle. When the CM7 sees (-) negative
input, it will delay the crank output for 99 seconds or until negative signal has been removed.
FO2 - Program (3-99 seconds): default setting is 12 seconds. This option allows the installer to
adjust the time in 1 second increments that the CM7 waits before cranking the starter.
FO3 - 7 seconds: This option offers a fixed 7 second delay before providing starter output.
FO4 - GM Ignition delay: This option is designed to delay the ignition output 250mS during the
remote start procedure. This allows for the accessory to output first, then ignition, to simulate normal
key starting. There are some vehicle models that may require this additional delay in order for it to
remote start properly.
Copyright 2014 Firstech, LLC.
Alarm and Starter System
techfeed.compustar.com
Page 33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents