Firstech CM7000 Master Manual page 34

Alarm and starter
Hide thumbs Also See for CM7000:
Table of Contents

Advertisement

CM7000 Master Guide
2-04 Trigger Start: This feature changes the number of negative (-) pulsed inputs (min of 60mS per
pulse) on the trigger start input wire. (pink wire CN5). Note: If option 3 is selected and OEM
remote control feature is available through data, the Control Module will accept 3
OEM lock commands to activate the start sequence.
FO1 - Off: (default)
FO2 - Single pulse: This option will trigger the remote start sequence with a single pulsed input to
the trigger start wire. This is ideal when adding accessories that can trigger the CM7.
FO3 - Double pulse: This option will trigger the remote start sequence with 2 pulses to the trigger
start input wire. This can be used when integrating with an OEM keyless entry remote.
FO4 - Triple pulse: This option will trigger the start sequence with 3 pulses to the trigger start input
wire. This is ideal when trying to integrate the OEM keyless entry remote. Note: this option will also
allow the CM7 to accept a 3 pulse input from OEM remote commands through data.
2-05 Cold or Hot Start: Note: the Firstech Thermister temp sensor must be connected to the
CM7 in order to use these options. This feature turns on the cold/hot Timer start features.
FO1 - Off: (default)
FO2 - Cold start: This option enables the thermister when using Timer Start Mode. It will start the
car at the preset cold temperature (see feature 2-08) according to the selected timer start option (see
feature 2-06)
FO3 - Hot Start: This option enables the thermister when using Timer Start Mode. It will start the
car at the preset hot temperature (see feature 2-09) according to the selected timer start option. (see
feature 2-06)
FO4 - Cold And Hot start: This option enables the thermister when using Timer Start Mode. It will
start the car at the preset Cold and Hot temperature (see features 2-08 and 2-09) according to the
selected timer start option (see feature 2-06)
2-06 Timer Start: This feature is designed to allow the user to have the CM7 automatically remote start
at the end of a selected timed cycle. It also be controlled by the thermister so it will start at a specified
temperature at the end of the timed cycle.
FO1 - 3 hour cycle: (4 minute runtime, 8 minute runtime for diesel) Once Timer Mode is enabled
(see feature 2-13) the CM7 will wait 3 hours, remote start and run for 4 minutes unless the cold start
feature is enabled. If this is the case, the CM7 will check the temperature once every 3 hours. If it is
at or below the selected temperature, (see feature 2-08) it will start and run for 4 minutes. The same
procedure will apply to the hot start feature. If there is any interaction with the CM7 after timer mode
has been activated using the Firstech remote or accessory, timer mode will be cancelled and must be
re-started in order to start a new timed cycle.
FO2 - 1.5 hour cycle: (4 minute runtime, 8 minute runtime for diesel) Once timer mode is enabled
(see feature 2-13) the CM7 will wait 1.5 hours, remote start and run for 4 minutes unless the cold
start feature is enabled. If this is the case, the CM7 will check the temperature once every 1.5 hours.
If it is at or below the selected temperature, (see feature 2-08) it will start and run for 4 minutes. The
same procedure will apply to the hot start feature. If there is any interaction with the CM7 after timer
mode has been activated using the Firstech remote or accessory, timer mode will be cancelled and
must be re-started in order to start a new timed cycle.
Copyright 2014 Firstech, LLC.
Alarm and Starter System
techfeed.compustar.com
Page 34

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents