CM7000 Master Guide
3-10 Valet Mode: This feature will change the enter/exit valet mode procedure based on the option
selected.
FO1 - Key 5 times with Foot Brake Trigger or Remote (Lock + Trunk) while Ignition is
on: This option allows the user to enter valet mode using either method described. Note: the user
may exit valet mode with their Firstech remote (please check users guide for each
remote for valet mode exit procedure), or with the key to ignition or "on" position
and press the foot brake 10 times within 10 seconds.
FO2 - Key 5 times with Foot Brake Trigger or Remote (Lock + Trunk): This option allows
the user to enter valet mode using either method described. Note: the user may exit valet mode
with their Firstech remote (please check users guide for each remote for valet mode
exit procedure), or with the key to ignition or "on" position and press the foot brake
10 times within 10 seconds.
3-11 Auxiliary Settings: (2 Way LCD remote required) this feature enables access to AUX 3 through 7
via any Firstech 2 way LCD remote.
FO1 - Off: (Default) This option will prevent the user form activating AUX 3-7 with the Firstech 2way
LCD remote.
FO2 - On: This feature will allow the user to enable AUX 3-7 which can be activated using a Firstech
2 way LCD remote. (Please refer to the remote users guide for specific AUX 3-7 activation process)
3-12 VAC: (Thermister required) this determines the temperature at which the CM7 will provide an output
on any POC programmed with setting 22(VAC: Ventilation-Air Conditioning) which can be used to
vent widows, activate AC controls, or cooling seats.
FO1 - 100°F: This option will provide a pulsed output on any POC programmed with setting 22
(VAC) if the temp sensor reads at or above 100°F with remote start confirmation.
FO2 - 90°F: This option will provide a pulsed output on any POC programmed with setting 22 (VAC)
if the temp sensor reads at or above 90°F with remote start confirmation.
FO3 - 80°F: This option will provide a pulsed output on any POC programmed with setting 22 (VAC)
if the temp sensor reads at or above 80°F with remote start confirmation.
FO4 - 90°F: Latched output: this option will provide a latched output for the selected runtime on any
POC programmed with setting 22 (VAC) if the temp sensor reads at or above 90°F.
3-13 Defrost output Temperature Control: This feature will determine the temperature at which the
CM7 will provide an output on any POC programmed with setting 17 or 21 (defrost and defrost 2).
FO1 - Standard: (Default) this option will provide an output (length of output based on feature
3-13 option settings) on any POC programmed with setting 17 (defrost) or 21 (defrost 2) every time
with remote start confirmation.
FO2 - 32°F: (Thermister required) this option will provide an output on any POC programmed with
setting 17 (defrost) or 21 (defrost 2) with remote start confirmation on. This will happen if the temp
reading is at or below 32°F. (Length of output based on feature 3-13 option settings)
FO3 - 42°F: (Thermister required) this option will provide an output on any POC programmed with
setting 17 (defrost) or 21 (defrost 2) with remote start confirmation on. This will happen if the temp
reading is at or below 42°F. (Length of output based on feature 3-13 option settings)