Firstech CM7000 Master Manual page 20

Alarm and starter
Hide thumbs Also See for CM7000:
Table of Contents

Advertisement

CM7000 Master Guide
Pin 2 Brown - Siren: 1A (+) output can be connected to the positive lead of an aftermarket siren.
Pin 3 White - [POC 2] AUX1: 250mA negative (-) output. This is an optional output that will provide a
pulsed, latched, or timed negative output when triggered by the remote(s). This can be used for power
sliding doors, window modules or other outputs. Note: there is an update available for the
OP500 which will extend the timed output options up to 15 minutes. Note: There are
28 additional POC setting options for this POC.
Pin 4 Light Blue/White - Brake 12V positive (+) input: This wire must be connected as it provides a
shut down for the remote start. It is also required to enter and exit Valet Mode. The proper wire will test
(+) 12V while the foot brake is pressed.
Pin 5 Blue/Black - [POC 3] Lock 250mA (-) negative output: This is an optional output that will provide
only negative (-) output pulse for locking doors. System will lock doors and arm alarm. IMPORTANT:
You must reverse polarity for (+) trigger door lock systems using the FT-DM700, FT-DM600 or relays.
For additional lock settings review Option Group 1. Note: There are 28 additional POC
settings for this POC.
Pin 6 Light Blue - [PIC 1] Parking / Emergency brake negative (-) programmable input: This input is
required for manual transmission/reservation and Turbo Timer mode. The proper e-brake wire will
provide a (-) trigger when parking / emergency brake is set and the key is in the ignition or "on"
position. This wire or input is required for manual transmission and turbo timer mode. There are
additional options for this PIC please check feature 2-14.
Pin 7 Blue - [POC 4] Unlock 250mA (-) negative output: This is an optional output that will provide only
a negative (-) output pulse for unlocking doors. System will unlock doors and disarm alarm.
IMPORTANT: You must reverse polarity for (+) trigger door lock systems using the FT-DM700, FT-
DM600 or relays. For additional lock settings review Option Group 1. Note: There are 28
additional POC setting options for this POC.
Pin 8 Violet/Black - [PIC 2) Trunk zone input (-) programmable input: This is an optional input that will
monitor when the vehicle's trunk has been opened. The proper wire will provide a (-) trigger while the
trunk is open.
Pin 9 Orange/White - [POC 5] Factory Alarm Disarm (FAD) 250mA negative (-) output: This output
will provide a (-) pulse during unlock and every time prior to the GWR (ground when running: aka.
Status output) turning on during the remote start sequence. It is typically used to disarm factory security
systems. Note: There are 28 additional POC setting options for this POC.
Pin 10 Red/White - Door zone input (-/+) Jumper programmable polarity: This wire monitors negative
(-) or positive (+) trigger door-pins. The proper wire will provide a (-) trigger or a (+) trigger only
when the doors are opened. You will need to test the wire for proper polarity and set the jumper
on the control module for the corresponding polarity. IMPORTANT: This wire is required for
manual transmission remote starts.
Copyright 2014 Firstech, LLC.
Alarm and Starter System
techfeed.compustar.com
Page 20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents