Ntp Configuration And Time Synchronization; The Cd-Rw/Dvd-Rw Drive Unit And Tape Drive Unit - Fujitsu SPARC EnterpriseM3000 User Manual

Table of Contents

Advertisement

1.3.2

NTP Configuration and Time Synchronization

The system uses the XSCF Unit clock for the system standard time.
The domains in the server synchronize their times based on the XSCF Unit clock
when the domains are started. The XSCF Unit clock can be adjusted to the exact time
through a network connection to an external NTP server. In that way, the XSCF Unit
becomes the NTP server and an NTP client.
Only domains may specify XSCF as an NTP server. Also, when the XSCF is used as
an NTP server, XSCF permits only the confirmation of the time synchronization to
the inquiry from the NTP client.
Note – Alternatively, the domains can synchronize their times through a connection
to an external NTP server. However, there is a possibility that time differences exist
between the XSCF and the domain. If you connect the domain to an external NTP,
connect the high rank NTP server that supplies the time of the same accuracy as the
domain as for XSCF.
For details about NTP server setting, see
TABLE 1-5
XSCF Unit and Domain Time Synchronization
TABLE 1-5
Client
Primary NTP Server
Domain
XSCF Unit
External NTP server
XSCF
No connection
External NTP server
1.3.3
The CD-RW/DVD-RW Drive Unit and Tape Drive
Unit
In the M3000 server, one domain monopolizes the DVD drive unit. In the
M4000/M5000 servers, the domain that uses a minimum XSB number of number 0 of
the MotherBoard Unit (MBU#0) can use the CD-RW/DVD-RW drive unit and tape
drive unit (hereafter collectively called DVD drive/tape drive unit).
1-20
SPARC Enterprise Mx000 Servers XSCF User's Guide • January 2012
outlines XSCF and domain time synchronization methods.
Time Synchronization Method
The domain time is adjusted to the XSCF Unit clock time.
XSCF Unit operates as the NTP server.
The domain time is adjusted to the standard time of the external NTP
server.
The XSCF Unit time is the time in initial system settings or the time
set by the setdate(8) command. For details on the setdate(8)
command, see the XSCF Reference Manual.
The XSCF Unit time is adjusted to the standard time of the external
NTP server.