Saving the Configuration Information to a Specified Target Directory
Over a Network
Command operation
1. Perform the dumpconfig(8) command specifying the target directory.
XSCF> dumpconfig ftp://server/backup/backup-sca-ff2-16.txt
:
2. When the data transfer is complete, confirm the identification data in the head
of the saved configuration file.
Note – For detail of dumpconfig(8) command, including how to enable encryption,
see the man page or the XSCF Reference Manual.
The form of the saved configuration file is as follows.
File name :
User specification
File format :
Text-encoded in base64 encoding
The following is the procedure for restoring configuration information.
Restoring the Configuration Information by Connecting the USB Device
for Exclusive Use to the Panel of the XSCF Unit
Note – To view XSCF messages in the following procedure, connect a serial
connection terminal to the XSCF Unit.
Command operation
1. Power off all domains.
2. Connect a USB device containing the saved configuration file to the USB
connector mounted on the XSCF Unit panel.