The following is the procedure for saving logs.
Saving the Logs by Connecting the USB Device for Exclusive Use to the
Front Panel of the XSCF Unit
Web browser operation
1. Select the snapshot (Note) menu for saves of the logs menu and display the
saving operation page.
2. Connect a USB device to the USB connector mounted on the XSCF Unit panel.
3. In the window, select the USB device on the XSCF Unit panel.
4. Set the encryption password used for encrypting the output log file.
5. Execute the data transfer. When the data transfer is complete, please contact
authorized service personnel.
Note – The snapshot menu may be displayed as "Data Collector".
Command operation
1. Connect a USB device to the USB connector mounted on the XSCF Unit panel.
2. Perform the snapshot(8) command and specify the local USB device on the
XSCF Unit for the output file (see Note).
XSCF> snapshot -d usb0
3. When the data transfer is complete, please contact authorized service
personnel.
Note – For details on using the snapshot(8) command, including how to enable
encryption, see the man page or the XSCF Reference Manual.
Saving the Logs to a Specified Target Directory Over a Network
Web browser operation
1. Select the snapshot menu for saving the log menu and display the saving
operation page.
2. In the window, select the download button and specify the target directory.
Chapter 8
Upgrade of XSCF Firmware and Maintenance
8-29