testsb(8)
EXAMPLES
498
Performs the initial diagnosis on PSB#00.
EXAMPLE 1
testsb 0
XSCF>
Initial diagnosis is about to start, Continue?[y|n] :
SB#00 power on sequence started.
0end
Initial diagnosis started. [1800sec]
0..... 30..... 60..... 90.....120end
Initial diagnosis has completed.
SB power off sequence started. [1200sec]
0.end
SB powered off.
XSB
Test
Fault
---- ------- --------
00-0 Passed
Normal
00-1 Passed
Normal
00-2 Passed
Normal
00-3 Passed
Normal
Performs an initial diagnosis of PSB#01 with detailed messages displayed.
EXAMPLE 2
testsb -v 1
XSCF>
Initial diagnosis is about to start. Continue? [y|n] :
SB#01 powered on sequence started.
:
:
Initial diagnosis has completed.
{0} ok SB power off sequence started. [1200sec]
0.end
SB powered off.
XSB
Test
Fault
---- ------- --------
01-0 Passed
Normal
Performs the initial diagnosis on all the PSB that are mounted.
EXAMPLE 3
testsb -c all
XSCF>
Initial diagnosis is about to start. Continue? [y|n] :
SB power on sequence started.
0end
Initial diagnosis started. [1800sec]
0..... 30..... 60..... 90.....120end
Initial diagnosis has completed.
SB power off sequence started. [1200sec]
0.end
SB powered off.
XSB
Test
Fault
---- ------- --------
00-0 Passed
Normal
01-0 Passed
Normal
02-0 Passed
Normal
03-0 Passed
Normal
Ignores the settings for the warm-up time of the system and the wait time
EXAMPLE 4
before system startup to perform the initial diagnosis on the PSB that are
XSCF Reference Manual • Last Revised January 2007