Fujitsu SPARC Enterprise M4000 Reference Manual page 423

Xscf control package (xcp) 106x
Hide thumbs Also See for SPARC Enterprise M4000:
Table of Contents

Advertisement

XSB is installed in the domain and this domain is power ON status, power
OFF status, or reset status.
The addboard(8), deleteboard(8), or moveboard(8) command is executed
for XSB.
In case an XSB which belongs to the specified PSB is in Unmount or Faulted
status, it may be excluded from the target of diagnosis and may not be shown in
the diagnosis result. In a case like this, use the testsb(8) command to check the
diagnosis result.
In case there are the settings for the warm-up time of the system and the wait
time before system startup, a prompt appears to confirm whether or not it can
ignore these settings to execute the testsb(8) command. Enter "y" to execute the
command or "n" to cancel the command.
The displayed diagnostic results of the testsb(8) command are as follows:
XSB numbers belonging to the specified PSBs. One XSB number
XSB
is displayed for the Uni-XSB type, and four XSB numbers are
displayed for the Quad-XSB type.
Status of the initial diagnosis of XSBs. One of the following
Test
status values is displayed:
Unmount
Unknown
Testing
Passed
Failed
XSB error. One or more states are displayed:
Fault
Normal
Degraded
Faulted
System Administration
No XSB could be recognized because no XSB
is mounted or because an error occurred.
Not tested.
Initial diagnosis is in progress.
Initial diagnosis ended normally.
An error was detected during the initial
diagnosis. An XSB cannot be used or is in a
degraded state.
Normal state.
One or more components are degraded.
Each XSB can operate.
An XSB cannot operate because an error
occurred.
testsb(8)
497