Flash Options; Dram Options; Hard Disk Option; Network Card Option - Lexmark C925 Service Manual

Led color printer
Hide thumbs Also See for C925:
Table of Contents

Advertisement

Flash options

Run a copy of the test page, and check to see if the option you are checking is listed. The printer does not
recognize the option being installed if the option is not listed. Be sure the memory card assembly is installed
correctly and is not broken or damaged. If the Memory card assembly is correctly installed, not broken or
damaged, then run the
"Flash Test" on page
problem continues, replace the RIP board.

DRAM options

This service check is the same as the flash memory option service check with the following exception: Run the
"DRAM Test" on page 3-17
broken or damaged. If the test fails, replace the DRAM card assembly. If the problem continues, replace the RIP
board.

Hard disk option

Service Tip: The 5041-030 printers support one hard disk option. Be sure only one hard disk option is installed.
Be sure the hard disk and the hard disk board are correctly installed. Run the
from the Device Test on the Diagnostic Menu.
Note: The Quick Disk Test is a non-destructive test and indicates Pass or Fail. If the test fails, replace the
hard disk. If a problem still exists, replace the RIP board.
Use the
"Disk Test/Clean" on page 3-19
test is divided into a cleaning and a verifying or testing section.
Warning: This can be a very lengthy test depending on the disk size. This test leaves the hard disk
unformatted. The servicer or user must reformat the disk using the Format Disk Menu operation. This is a
destructive type of test. All the data on the disk is destroyed and should not be performed on a known good
disk.

Network card option

The network is installed on the system board on network model printers. See
install needed)" on page
2-60.

Error code 976 - Network card x

A 976 error code indicates an unrecoverable software error in network card x. Verify that network card x is
correctly installed and all the IPSP cables are properly connected. If you find no problem, contact your next level
of support before replacing the network card.
54 Network <x> Software error
This error displays when the RIP software detects that a network card is installed in slot x on the interconnect
board but cannot establish communications with the network card.
3-20. If the test fails, replace the Flash card assembly. If the
from the menu if the DRAM Memory card assembly is correctly installed and not
to help restore the disk if it contains bad data and is unusable. This
5041-030
"Quick Disk Test" on page 3-19
"Networking service check (ISP
Diagnostic information