Soft Switch: #62; Soft Switch: #63 - Konica Minolta bizhub 160 Service Manual

Service manual
Hide thumbs Also See for bizhub 160:
Table of Contents

Advertisement

Field Service Ver. 1.0 Apr. 2005
16.8.64

SOFT SWITCH: #62

Bit
Designation
No.
8
Reserved
7
Reserved
6
Reserved
5
Reserved
4
Reserved
3
Reserved
2
Reserved
1
Reserved
16.8.65

SOFT SWITCH: #63

Bit
Designation
No.
8
# key definition in PBX
mode
7
Reserved
6
Reserved
5
Reserved
4
Reserved
3
Reserved
2
Reserved
1
Tx Result report with
image
• Bit 8: if this bit set to "1", the # key is used to access PSTN line instead of the pre-fix
number which is dialed in front of the TEL No. If this bit set to 0, the pre-fix number
is used automatically to access PSTN line when the TEL No. is dialed.
• Bit 1: If this bit set to "1", the first page image will not append at the bottom of error report
or OK report
16. Soft Switch Set (bizhub 160f/bizhub 161f only)
Function
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Function
0: default is internal
1: default is external
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
0: Yes
1: No
Initial
Setting
Bit HEX
0
0
0
0
0
0
0
0
0
0
Initial
Setting
Bit
HEX
1
8
0
0
0
0
0
0
0
0
227