3. Periodical check
3.4.3
Replacement of the Image Transfer Roller
16
1. Remove the Imaging Cartridge.
2. Place the levers of the Bearings
(white) on the right and left ends of
the Image Transfer Roller toward this
side and remove the Image Transfer
Roller from the Image Transfer Roller
holder.
4136E018AA
3. Pull out the Bearings on the right and
left ends, and the gear, from the
Image Transfer Roller removed from
its holder. Install the Bearings and
the gear to the new Image Transfer
Roller.
NOTE
• Do not touch, or dirty with chemi-
4136E019AB
cals or toner, the surface of the
Image Transfer Roller, as indenta-
tions in and dirt on the surface of
the Image Transfer Roller adversely
affect the quality of the printed
image.
• When handling the Image Transfer
Roller, hold onto the shaft and
Bearings of the roller.
• Do not place a new Image Transfer
Roller directly on the floor or other
surface.
4. Insert the new Image Transfer Roller
into the Image Transfer Roller holder
and place the levers of the Bearings
into the original upward positions.
4136E020AB
Field Service Ver. 1.0 Apr. 2005