16. Soft Switch Set (bizhub 160f/bizhub 161f only)
Switch
Bit No.
No.
# 12
8
ECM Mode capability
7/6
V.34 fall back level for V.34 TX.
5
Send CTC after 4th PPR
3
Send EOR after lowest speed
2/1
TCF transmission timing after DCS
# 13
8
MR capability for G3
7/6
Delay time between transaction
5
Super fine printing capability for receiving
4
Disable ultra fine capability in RX mode
3
DTS mode (Der Telefax Standard)
2
Send DTC signal if RX DIS signal in polling RX mode
# 14
6
Memory size level to RX
3/2/1
Time between V.34 ANSam signal and FSK DIS signal
# 15
1
Remote side no document to be polled
# 16
2/1
Fax communication coding method
# 17
6
CED frequency
5/4/3
Pause between off hook and CED signal
2/1
Inactivity timer [T5]
# 18
6/5
G3 mode training quality level
4/3/2/1
Redefine re-dial attempts counter
# 19
8/7/6/5
CNG signal level
4/3/2/1
DTMF high frequency level
# 20
5/4/3/2/1
Redefine redial interval
# 21
8
NSS signal before DCS
7/6
CNG duration after dialing (T1)
5
T4 timer
3
DIS signal length
2/1
Increase default T1 timing during calling
# 22
8
Detect busy tone before dial
7
Regard dial tone as busy tone after dialing
6
Check busy tone method
4/3/2/1
CED signal output level
# 23
-
Reserved
# 24
-
Reserved
# 25
4/3
Flash key time in ON hook key dial
# 26
8/7
Dial tone detection time before disconnected
6/5/4/3/2/1 Dial tone insensitivity
# 27
4/3/2/1
Immunity for dial tone receiver
# 28
8/7/6/5
Time to dial after dial tone on the line
# 29
5/4/3/2/1
Time to dial after size the line when dial tone detected
180
Field Service Ver. 1.0 Apr. 2005
Designation
Page No.
192
193
194
194
195
195
196
197
198
199
200
200
201
201
202
203
204
205

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub 160fBizhub 161Bizhub 161f

Table of Contents