Field Service Ver. 1.0 Apr. 2005
20.2.11
C133D: ROM Checksum Error
A. Detection Timing
• A malfunction occurred in the ROM.
B. Troubleshooting Procedures
Controller/Mechanical Control Board (PWB-P)
Step
1
Replace PWB-P.
20.2.12
C13F0: Laser Error
A. Detection Timing
• The laser output exceeds the upper limit value.
• The laser output remains lower than the lower limit value.
B. Troubleshooting Procedures
PH Unit
Flat cable
Step
1
Check cables for connection and correct
as necessary.
2
Replace PH Unit.
3
Replace PWB-P.
Description
Relevant Electrical Components
Action
Description
Relevant Electric Parts
Action
WIRING DIAGRAM
Control Signal
–
Controller/Mechanical Control Board (PWB-P)
WIRING DIAGRAM
Control Signal
–
–
–
20. Malfunction code
Location
(Electric Parts)
–
Location
(Electric Parts)
–
–
–
253