Konica Minolta bizhub 160 Service Manual page 307

Service manual
Hide thumbs Also See for bizhub 160:
Table of Contents

Advertisement

23. FAX error (bizhub 160f/bizhub 161f only)
Code
00B1
Did not finish V.8 procedure or detect V.21 signal after ANSam signal within 35 seconds.
00B2
Did not detect phase B signal after our side sending CJ signal within 30 seconds.
00B3
Did not detect correct V.21 or JM signal after sending CM signal.
00B4
Did not detect correct phase B signal within 25 second after CM/JM signal exchange.
00B5
Did not detect phase C signal after phase B within 25 seconds.
00B6
Did not detect phase D signal within 25 seconds after CM/JM exchange.
00B7
Did not detect phase E signal after phase D within 30 seconds.
00B8
Remote side disconnect after our side sent DCS signal in V.34.
00B9
Receive T.30 signal other than DIS,DCS,CFR after sending DCS signal in V.34.
00BA
Did not receive correct signal after our side sent DTC signal in V.34.
00BB
Every time our side received DIS signal after sending DTC in V.34.
00BC
Modem not ready within 10 second after entering primary channel in V.34.
00BD
Can not detect correct V.21 or JM signal after detected FSK frequency.
00BE
Remote side no document to be polled after V8 handshaking.
00BF
Capability not match after V8 handshaking.
00C0
Remote side disconnect before entering primary channel in V.34.
00C1
At phase-D, transmitting unit sends out EOP 3 times consecutively, but receives no answer
from receiving unit.
00C2
Remote side disconnect after sending out V.8 CM signal.
00C4
After sending MPS signal, the received signal is not one of MCF, RTN, PIP, PIN, RTP, DCN.
00C5
Received DCN signal after sending MPS signal.
00C9
At phase-D, sending MPS 3 times consecutively, but no answer from receiving unit.
00CA
After sending EOP signal, the received signal is not one of MCF, RTN, PIP, PIN, PRI-EOP,
DCN.
00CB
After sending EOP signal, the received signal is DCN signal.
00CC
After sending EOM signal, the received signal is not one of MCF, RTN, PIP, PIN, RTP, DCN.
00CD
At phase-D, transmitting unit sends out EOM 3 times consecutively, but receives no answer.
00CE
At phase-D, transmitting unit sends out EOM, but receives DCN.
00CF
Received incorrect signal after sending DTC signal for V.34 polling.
00D0
Received ERR signal after sending EOR_NULL.
00D1
ECM TX received wrong command in phase D after PPS-EOP. (not PPR, MCF, PIP,
PIN,.....).
00D2
Receive DCN after send command PPS-EOP signal.
00D3
Received DCN after sending PPS_NULL signal.
00D4
Received DCN after sending PPS_EOM signal.
00D8
Did not detect correct phase C signal for polling within 25 seconds.
00D9
Did not detect correct phase C signal after detecting silence after phase B.
00DA
Did not detect phase D signal within 30 seconds or remote side hang up over 6 seconds.
00DB
Did not receive any T.30 signal within 15 seconds in phase D.
00DC
Received T.30 signal in phase D other than DCS,DIS or DTC.
00DD
Remote side not the same model or no mailbox ID defined for mailbox TX.
00DE
Remote side no SUB capability in V.34.
274
Field Service Ver. 1.0 Apr. 2005
Possible Causes of Error.