23. FAX error (bizhub 160f/bizhub 161f only)
Code
0031
Received incorrect signal at phase D (not EOP, MPS, EOM, DCS PPS_Q, PPS_Q, etc.).
0032
Did not receive carrier signal within 6 sec.after sending MCF. or RTP, RTN signal.
0033
Received DCN signal at phase D within pages (not last page).
0039
In non-ECM mode, when machine already received the data but next line data doesn't
receive within 13.1 seconds.
003F
Remote side TSI not programmed in machine one touch or speed dial directory.
0040
Did not receive carrier signal within 6 sec. after sending CTR.
0041
Did not receive carrier signal within 6 sec. after sending PPR.
0042
Did not receive correct signal after sending RNR signal.
0043
Received incorrect signal at phase D in ECM mode.
0044
Did not receive carrier signal /FSK signal within 6 sec. after sending MCF in ECM mode.
0045
Did not receive any correct signal after sending RNR response with ERR signal.
0046
Receive incorrect signal when sending RNR response with ERR signal.
0047
Did not receive correct signal after sending ERR signal.
0048
Did not receive correct signal after receiving PPS_PRI_Q or PRI_Q, EOR_PRI_Q.
0049
Did not receive correct signal after sending PIP/PIN signal within 13 sec.
004A
Line energy over threshold lasts for 60 seconds after MCF and can not detect FSK or carrier
signal in ECM mode.
004B
Can not detect correct FSK signal even though detected FSK tone within 6 sec.
004C
Command hand shake fail when V.34 RX.
004E
Receive DCN signal after sending DIS in V.34.
004F
Remote side disconnected after sending ANSam in V.8 phase.
0050
Did not receive any correct signal after sending CJ signal in V.8 phase.
0051
Did not receive phase C signal after phase B within 20 seconds in V.34.
0052
Did not receive phase D signal after phase C within 20 seconds in V.34.
0053
Modem disconnect after phase D in V.34.
0054
Remote side disconnected after phase D in V.8.
0055
Receive incorrect signal after sending DIS signal in V.34.
0056
Modem disconnect after sending CFR in V.34.
0057
Did not detect image signal within 6 seconds after sending CFR.
0058
Did not detect image signal within 6 seconds after modem enter to phase A in V.34.
0059
Relay box is not registered even when Relay job has been received.
005A
Modem can not detect any correct ECM frame within 3 minutes in phase C.
005B
Did not detect phase E signal after primary channel within 6 seconds.
005C
Detect busy tone within control channel after phase C.
005D
Remote-side disconnect at phase C (V.34).
005E
Did not detect control channel signal after received RCP frame within 6 seconds.
005F
Did not detect silence after sending JM signal for polling TX function.
0060
There are no bulletin files to be polled in V.34.
0061
Machine can not detect V.21 or V.8 signal within 35 seconds.
0062
Modem disconnect in phase D after our side sending out flag sequence in control channel.
0063
Did not receive any flag sequence in control channel within 6 seconds in phase D.
272