Checking The Status Of The User Port; Querying The Adsl Port Status; Reproduction And Communication In Any Form Prohibited Without The Written Permission Of Sagem Sa - Sagem 4450E Hardware Installation Manual

Triple play access concentrator
Table of Contents

Advertisement

Table 1-3 Parameter table on the modules of SFP optical interface
Type
SFP-SM-155M-15K
SFP-SM-155M-40K
SFP-SM-155M-80K
SFP-SM-622M-15K
SFP-SM-622M-40K
SFP-SM-622M-80K
SFP-SM-1.25G-10K
SFP-SM-1.25G-30K
SFP-SM-1.25G-40K
SFP-SM-1.25G-70K
SFP-SM-1.25G-110K
SFP-SM-2.5G-15K
SFP-SM-2.5G-40K
SFP-SM-2.5G-70K
Table 1-4 Parameter table on the modules of XENPAK optical interface
Type
Xenpak-SM-10G-10K

8.2. Checking the Status of the User Port

8.2.
8.2.
8.2.

8.2.1. Querying the ADSL Port Status

8.2.1.
8.2.1.
8.2.1.
You can query the ADSL port information by executing the commands below:
show port [portlist|all|active] : Show the current information of the port
show port [portlist|all|active] adsl line-config : Show the configuration information of the
ADSL port
The first command is used to show the current information that is subject to update in real time. The second
command is used to show configuration information that does not vary with the port link status.
3P@C Installation Manual
Page 8-2 Reproduction and communication in any form prohibited without the written permission of SAGEM SA
Rate
Optical
Maximum
(bps)
fiber
transmissio
mode
n distance
155 M
Single
15
mode
155 M
Single
40
mode
155 M
Single
80
mode
622 M
Single
15
mode
622 M
Single
40
mode
622 M
Single
80
mode
1.25
Single
10
G
mode
1.25
Single
30
G
mode
1.25
Single
40
G
mode
1.25
Single
70
G
mode
1.25
Single
110
G
mode
2.5 G
Single
15
mode
2.5 G
Single
40
mode
2.5 G
Single
70
mode
Rate
Optical
Maximum
(bps)
fiber
transmis
mode
sion
distance
10 G
Single
10
mode
Optical
Transmitt
connect
ing
or type
center
waveleng
th (nm)
LC
1,310
LC
1,310
LC
1,550
LC
1,310
LC
1310
LC
1,550
LC
1,310
LC
1,310
LC
1,310
LC
1,550
LC
1,550
LC
1,310
LC
1,310
LC
1,550
Conne
Transmittin
ctor
g center
Type
wavelength
(nm)
SC
1310
SAGEM 3P@C
Transmit
Receivi
ting
ng
optical
overlo
power
ad
(dBm)
point
(dBm)
-15 ~ 0
-8
-5 ~ 0
-10
-5~0
-10
-15 ~ 0
-8
-5~ 2
-8
-5 ~ 2
-8
-5~0
-3
-4 ~ 2
-3
-5 ~ 2
-3
-2~5
-3
0 ~ 5
-9
-10 ~ 2
-9
-10 ~ 3
-9
-10 ~ 3
-9
Transmitti
Receivi
ng optical
ng
power
overloa
d point
(dBm)
-8.2~0.5
0.5
Receivi
ng
sensitivi
ty
((dBm)
-28
-34
-34
-28
-28
-28
-23
-20
-21
-22
-30
-18
-19
-19
Receivi
ng
sensitivi
ty
(dBm)
-10.3

Advertisement

Table of Contents
loading

This manual is also suitable for:

3p@c 4450e

Table of Contents