7.3.7. Viewing the Route Information
7.3.7.
7.3.7.
7.3.7.
Operation Guide
You can execute the command show ip route to query route information: Whether the route table is correct,
whether the configured static route and OSPF/RIP route have been learned or not, and whether the route is
selected correctly or not.
Reference index
For example:
3P@C(config)# show ip route
Codes: C - connected, S - static, R - RIP, O - OSPF
> - selected route, * - selected nexthop
S>* 0.0.0.0/0 [1/0] via 10.16.0.254, 3P@C
C>* 2.2.2.0/24 is directly connected, pppoe1
C>* 10.0.0.0/16 is directly connected, uplink
C>* 10.10.1.0/24 is directly connected, server2
S 10.10.1.0/24 [1/0] via 10.11.1.254 inactive
C>* 10.16.0.0/16 is directly connected, 3P@C
C>* 12.1.0.0/16 is directly connected, server
C>* 192.168.0.0/16 is directly connected, adsl
S>* 192.168.2.0/24 [1/0] via 192.168.1.3, adsl
7.3.8. Querying the System Running Time
Operation Guide
You can execute the command show running-time to query the system running time.
Reference index
The Current system time is consistent with Beijing time. The Running_time is correct.
For example:
3P@C(config)# show running-time
Running time is:0 days 1 hours 51 minutes 45 seconds
7.4. Handling Password Loss
Before equipment delivery, the default login user name is "admin", the default password is "3P@C", and the
default password for entering the configuration mode is also "3P@C". If the user modifies the above password,
the user must bear the new password in mind. If forgetting the new password, the user can follow the
procedures below:
Step 1: Power on the equipment, and press and hold <Space> to enter the BootROM menu. Select "g" (Boot an
executable image) to skip over password check.
3P@C Installation Manual
Page 7-18
Reproduction and communication in any form prohibited without the written permission of
SAGEM SA
SAGEM 3P@C