Hitachi SJ7002 Series Instruction Manual page 72

Sj7002 series
Hide thumbs Also See for SJ7002 Series:
Table of Contents

Advertisement

2–30
Using the Front Panel Keypad
Keys, Modes, and
Parameters
• Function Key – This key is used to navigate
through the lists of parameters and functions
for setting and monitoring parameter values.
2
• Up/Down (
,
) Keys – Use these
1
keys alternately to move up or down the lists
of parameter and functions shown in the
display, and increment/decrement values.
• Store (
) Key – When the unit is in
STR
Program Mode and the operator has edited a
parameter value, press the Store key to write
the new value to the EEPROM. This param-
eter is then displayed at powerup by default.
If you want to change the powerup default,
navigate to a new parameter value and press
the Store key.
Purpose of the keypad is to provide a way to change modes and parameters. The term function
applies to both monitoring modes and parameters. These are all accessible through function
codes that are primarily 3 or 4-character codes. The various functions are separated into related
groups identifiable by the left-most character, as the table shows.
Function
Type (Category) of Function
Group
"D"
Monitoring functions
"F"
Main profile parameters
"A"
Standard functions
"B"
Fine tuning functions
"C"
Intelligent terminal functions
"H"
Motor constant functions
"P"
Expansion card functions
"U"
User-selectable menu functions
"E"
Error codes
For example, function "A004" is the base frequency setting for the motor, typically 50 Hz or
60 Hz. To edit the parameter, the inverter must be in Program Mode (PGM LED will be ON).
You use the front panel keys to first select the function code "A004." After displaying the value
for "A004," use the Up/Down (
NOTE: The inverter 7-segment display shows lower case "b" and "d", meaning the same as the
upper case letters "B" and "D" used in this manual (for uniformity "A to F").
The inverter automatically switches into Monitor
Mode when you access "D" Group functions. It
switches into Program Mode when you access
any other group, because they all have editable
parameters. Error codes use the "E" Group, and
appear automatically when a fault event occurs.
Refer to
"Monitoring Trip Events, History, &
Conditions" on page 6–5
for error code details.
RUN
PRG
RUN
FUNC.
Function
key
Mode to Access
Monitor
Program
Program
Program
Program
Program
Program
Monitor
2
or
) keys to edit the value.
1
MONITOR
"D" Group
POWER
HITACHI
ALARM
60.0
HZ
V
kW
A
%
STOP
RESET
MIN
MAX
2
1
STR
Up/Down
Store
keys
key
PGM LED
Indicator
or
PROGRAM
"A" Group
"B" Group
"C" Group
"H" Group
"P" Group
"U" Group
"F" Group