Precautions For Emc, Models Sj700-1850 To -4000 - Hitachi SJ7002 Series Instruction Manual

Sj7002 series
Hide thumbs Also See for SJ7002 Series:
Table of Contents

Advertisement

Precautions for EMC, Models SJ700-1850 to -4000

The SJ700
(EMC) Directive (2004/108/EC). However, when using the inverter in Europe, you must
comply with the following specifications and requirements to meet the EMC Directive and
other standards in Europe:
WARNING: This equipment must be installed, adjusted, and maintained by qualified
engineers who have expert knowledge of electric work, inverter operation, and the hazardous
circumstances that can occur. Otherwise, personal injury may result.
Use the following checklist to ensure the inverter is within proper operating ranges and
conditions.
1. Power supply requirements
2. Installation requirements
Models
Cat.
length
SJ700-300L
C3
SJ700-370L
C3
SJ700-450L
C3
SJ700-550L
C3
series inverter conforms to the requirements of Electromagnetic Compatibility
2
a. Voltage fluctuation must be -15% to +10% or less.
b. Voltage imbalance must be ±3% or less.
c. Frequency variation must be ±4% or less.
d. Total harmonic distortion (THD) of voltage must be ±10% or less.
a. A special filter and a ferrite core intended for the SJ700
must be installed, shown in the table below.
b. A provided direct reactor with the SJ700 large capacity series inverter must be installed.
Filter
Power
supply
Direct
Reactor
Cable
Carrier
freq.
Models
(m)
(kHz)
5
2.5
SJ700-300H
5
2.5
SJ700-370H
5
2.5
SJ700-450H
5
2.5
SJ700-550H
SJ700-750H
SJ700-900H
SJ700-1100H
SJ700-1320H
SJ700-1500H
Ferrite
core 1
Inverter
R, S, T
Ferrite
core 2
P, PD
SJ700
Inverter
2
Cable
Carrier
Cat.
length
freq.
(m)
(kHz)
C3
1
2.5
C3
1
2.5
C3
5
2.5
C3
5
2.5
C3
10
2.5
C3
10
2.5
C3
10
2.5
C3
10
2.5
large capacity series inverter
2
U, V, W
Motor
D–5

Advertisement