2–24
Step-by-Step Basic Installation
Internal
EMC Filter
Status
Disabled
Enabled
Inverter model: –750 to 1500HFU2
R
(L1)
(G)
Inverter model: –1850HFU2, HFE2
R
T
0
0
R
S
(G)
(L1)
(L2)
Jumper
Inverter model: –3150HFU2, HFE2
R
T
0
0
S
R
T
(L2)
(G)
(L1)
(L3)
Inverter model: –4000HFU2, HFE2
R
T
0
0
R
S
T
(G)
(L1)
(L2)
(L3)
The table below lists the nominal current that may leak from only the inverter when the internal
EMC filter is enabled or disabled. Leakage current is in proportion to input power voltage and
frequency. The values do not exclude current leakage from external devices and equipment
(e.g., power cables). Inverter models from 75 kW to 132 kW does not have a switch to enable/
disable the internal EMC filter. This complies EMC directive C3 level in standard condition.
200V Class Inverters
Units
(Input voltage = 200VAC, 50 Hz)
kW
0.4 – 3.7 5.5 – 11
~mA
0.1
0.1
~mA
2.5
48
S
T
PD
P
(L2)
(L3)
(+1)
(+)
Jumper
T
PD
P
N
(L3)
(+1)
(+)
(–)
(T1)
P
(+)
bar
P
(+)
PD
N
P
(+1)
(–)
(+)
P
(+)
PD
P
N
(+1)
(+)
(–)
Jumper
bar
(Input voltage = 400VAC, 50 Hz)
15–37
45–55
.75–3.7
0.1
0.1
0.2
23
23
5
R
T
0
0
N
U
V
W
(–)
(T1)
(T2)
(T3)
bar
(G)
U
V
W
(T2)
(T3)
(G)
V
U
W
(T2)
(T1)
(T3)
(G)
U
V
W
(T1)
(T2)
(T3)
(G)
400V Class Inverters
5.5–11
15–37
45–55
0.2
0.2
0.2
95
56
56
75–132
0.2