3–54
"C" Group: Intelligent Terminal Functions
Option
Terminal
Code
Symbol
55
FOC
56
MI1
57
MI2
58
MI3
59
MI4
60
MI5
61
MI6
62
MI7
63
MI8
65
AHD
66
CP1
67
CP2
68
CP3
69
ORL
70
ORG
71
FOT
72
ROT
73
SPD
74
PCNT
75
PCC
no
Input Function Summary Table
Function Name
Current forcing
General-purpose input 1
General-purpose input 2
General-purpose input 3
General-purpose input 4
General-purpose input 5
General-purpose input 6
General-purpose input 7
General-purpose input 8
Analog holding command Causes the inverter to sample and hold the analog speed input,
Multi-stage position
select 1
Multi-stage position
select 2
Multi-stage position
select 3
Zero-return limit function Indicates that the load has reached the zero-return point, so
Zero-return trigger
function
Forward drive stop
Reverse drive stop
Speed/position control
select
Pulse counter input
Pulse counter clear
Not selected
Description
Forces excitation current in motor at 0 speed; for use with V/f
curve settings A044/A244 = 03, 04, and 05
Easy sequence function, general input 1
Easy sequence function, general input 2
Easy sequence function, general input 3
Easy sequence function, general input 4
Easy sequence function, general input 5
Easy sequence function, general input 6
Easy sequence function, general input 7
Easy sequence function, general input 8
maintaining constant speed while this signal is ON
Binary-encoded position select, bit 1 (LSB)
Binary-encoded position select, bit 2 (LSB)
Binary-encoded position select, bit 3 (MSB)
the inverter stops the zero-return operation in progress
Starts a zero-return operation (load moves toward the zero-
return point)
Limits the forward rotational torque to 10%; for use at the end
of travel in position control mode
Limits the reverse rotational torque to 10%; for use at the end
of travel in position control mode
Causes the inverter to perform only speed control (ignores
encoder pulses) while in position control mode
Pulse counter input
Clears the pulse count
(input ignored)