B096
Dynamic braking activation level
B098
Thermistor for thermal
protection control
B099
Thermal protection level setting
Thermistor resistance threshold at which trip occurs
B090: Dynamic braking usage ratio – This parameter limits the amount of time the inverter
can use the dynamic braking accessory device without entering the Trip Mode. Please refer to
"Dynamic Braking" on page 5–6
NOTE: When cooling fan control is enabled (B092=01) the inverter always turns the fan ON
for five minutes immediately after powerup. This will cool the inverter in case the inverter /
motor is still warm from prior running before a short power outage.
Free-setting
The free-setting V/f inverter mode of operation uses voltage and frequency parameter pairs to
V/f Pattern
define seven points on a V/f graph. This provides a way to define a multi-segment V/f curve
that best suits your application.
The frequency settings do require that F1 ≤ F2 ≤ F3 ≤ F4 ≤ F5 ≤ F6 ≤ F7; their values must have
this ascending order relationship. To satisfy this criterion during initial parameter editing, set
F7 (B112) and work backwards when setting these values, since the defaults are all 0 Hz.
However, the voltages V1 to V7 may either increase or decrease from one to the next. There-
fore, you may set these parameters in any order.
Func.
Code
B100
Free-setting V/f frequency (1)
B101
Free-setting V/f voltage (1)
B102
Free-setting V/f frequency (2)
B103
Free-setting V/f voltage (2)
B104
Free-setting V/f frequency (3)
B105
Free-setting V/f voltage (3)
B106
Free-setting V/f frequency (4)
B107
Free-setting V/f voltage (4)
B108
Free-setting V/f frequency (5)
B109
Free-setting V/f voltage (5)
B110
Free-setting V/f frequency (6)
B111
Free-setting V/f voltage (6)
B112
Free-setting V/f frequency (7)
B113
Free-setting V/f voltage (7)
Keypad
SRW
OPE
330 to 380 (V) (200V class),
660 to 760 (V) (400V class)
00
OFF
Disable
0 1
PTC
Enable-PTC thermistor
02
NTC
Enable-NTC thermistor
0.0 to 9999 Ohms
Name/
Description
0. to Free-setting V/f frequency (2) (Hz)
0.0 to 800.0 (V)
0. to Free-setting V/f frequency (3) (Hz)
0.0 to 800.0 (V)
0. to Free-setting V/f frequency (4) (Hz)
0.0 to 800.0 (V)
0. to Free-setting V/f frequency (5) (Hz)
0.0 to 800.0 (V)
0. to Free-setting V/f frequency (6) (Hz)
0.0 to 800.0 (V)
0. to Free-setting V/f frequency (7) (Hz)
0.0 to 800.0 (V)
0. to 400.0 (Hz)
0.0 to 800.0 (V)
Range and Settings
for more information on dynamic braking accessories.
Range and Settings
3–47
SJ700
Inverter
2
Defaults
Run
Mode
FEF2
FUF2
FF2
Edit
FE2
FU2
F2
Lo Hi
(EU)
(USA)
(Jpn)
✘ ✔
360/
360/
360/
720
720
720
✘ ✔
00
00
00
✘ ✔
✘ ✔
✘ ✔
3000
3000
3000
✘ ✔
Defaults
Run
Mode
FEF2
FUF2
FF2
Edit
FE2
FU2
F2
Lo Hi
(EU)
(USA)
(Jpn)
✘ ✘
0.
0.
0.
✘ ✘
0.0
0.0
0.0
✘ ✘
0.
0.
0.
✘ ✘
0.0
0.0
0.0
✘ ✘
0.
0.
0.
✘ ✘
0.0
0.0
0.0
✘ ✘
0.
0.
0.
✘ ✘
0.0
0.0
0.0
✘ ✘
0.
0.
0.
✘ ✘
0.0
0.0
0.0
✘ ✘
0.
0.
0.
✘ ✘
0.0
0.0
0.0
✘ ✘
0.
0.
0.
✘ ✘
0.0
0.0
0.0

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents