Hitachi SJ7002 Series Instruction Manual page 145

Sj7002 series
Hide thumbs Also See for SJ7002 Series:
Table of Contents

Advertisement

Serial
The following table configures the communications port of the SJ700
up to thirty-two devices on the serial communications network. The inverters are slaves and the
Communications
computer or digital operator is the master. Thus, all inverters on the serial connection must use
the same baud rate, data length, parity, and stop bits. However, each device on the serial
network must have a unique node address. See
information.
Func.
Name/
Code
Description
C071
Communication speed
selection
C072
Node allocation
Set the address of the inverter on the network
C073
Communication data length
selection
C074
Communication parity
selection
C075
Communication stop bit
selection
C076
Action upon communication
error selection
C077
Communication timeout before trip
C078
Communication wait time
Time the inverter waits after receiving a message before it transmits
C079
Communication protocol
select
Keypad
Range and Settings
SRW
OPE
02
TEST
Test
03
2400bps
2400 (bps)
04
4800bps
4800 (bps)
05
9600bps
9600 (bps)
06
19200bps
19200 (bps)
1. to 32. (node)
07
7BIT
7-bit data
08
8BIT
8-bit data
00
NO
No parity
0 1
EVN
Even parity
02
ODD
Odd parity
0 1
1BIT
1 Stop bit
02
2BIT
2 Stop bits
00
Trip
TRP
0 1
DSTP
Trip after deceleration and stop
02
NEG
No action (ignore errors)
03
FRS
Free-run stop
04
DTP
Decelerate and stop
0.00 to 99.99 (seconds)
0.0 to 1000 (milliseconds)
00
ASCII
ASCII
0 1
ModBus RTU
Modbus
SJ700
inverter. You can have
2
"Serial Communications" on page B–1
Defaults
xFE2
xFU2
(EU)
(USA)
04
04
1.
1.
07
07
00
00
1
02
02
0.00
0.00
0.
0.
00
00
3–61
Inverter
2
for more
Run
Mode
xFF2
Edit
(Jpn)
Lo Hi
✘ ✔
04
✘ ✔
1.
✘ ✔
07
✘ ✔
00
✘ ✔
1
1
✘ ✔
02
✘ ✔
0.00
✘ ✔
0.
✘ ✔
00