Func.
Code
C015
Terminal [5] active state
C016
Terminal [6] active state
C017
Terminal [7] active state
C018
Terminal [8] active state
C019
Terminal [FW] active state
NOTE: An input terminal configured for option code 18 ([RS] Reset command) cannot be
configured for normally closed operation.
Intelligent Input
Each of the eight intelligent terminals may be assigned any of the options in the following
Terminal
table. When you program one of the option codes for terminal assignments C001 to C008, the
respective terminal assumes the function role of that option code. The terminal functions have a
Overview
symbol or abbreviation, which we use to label a terminal using that function. For example the
"Reverse Run" command is [RV]. The physical label on the terminal block connector is simply
1, 2, 3, 4, 5, 6, 7, or 8. However, schematic examples in this manual also use the terminal
function symbol (such as [RV]) to show the assigned option. The option codes for C011 to
C019 determine the active state of the logical input (active high or active low).
Summary Table - This table shows all forty-four intelligent input functions at a glance.
Detailed descriptions of these functions, related parameters and settings, and example wiring
diagrams are in
Option
Terminal
Code
Symbol
01
RV
02
CF1
03
CF2
04
CF3
05
CF4
06
JG
07
DB
Keypad
Name/
Description
SRW OPE
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
"Using Intelligent Input Terminals" on page
Input Function Summary Table
Function Name
Reverse Run/Stop
Multi-speed select,
Bit 0 (LSB)
Multi-speed select,
Bit 1
Multi-speed select,
Bit 2
Multi-speed select,
Bit 3 (MSB)
Jogging
External Signal for DC
Injection Braking
Range and Settings
00
Normally open (N.O.)
0 1
Normally closed (N.C.)
00
Normally open (N.O.)
0 1
Normally closed (N.C.)
00
Normally open (N.O.)
0 1
Normally closed (N.C.)
00
Normally open (N.O.)
0 1
Normally closed (N.C.)
00
Normally open (N.O.)
0 1
Normally closed (N.C.)
Description
Puts the inverter in Run Mode, motor runs reverse
Binary encoded speed select, Bit 0
Binary encoded speed select, Bit 1
Binary encoded speed select, Bit 2
Binary encoded speed select, Bit 3
Puts the inverter in Run Mode, output to motor runs at jog
parameter frequency A038
Applies DC braking during deceleration
SJ700
Inverter
2
Defaults
Mode
FEF2
FUF2
FF2
FE2
FU2
F2
Lo Hi
(EU)
(USA)
(Jpn)
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
4–13.
3–51
Run
Edit
✘ ✔
✘ ✔
✘ ✔
✘ ✔
✘ ✔
✘ ✔
✘ ✔
✘ ✔
✘ ✔
✘ ✔

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents