Selecting the Calibrate Laminator tab

The Calibrate Laminator tab is active when the Laminator is automatically detected or when
the Laminator is manually checked (as a Printer Feature on the Configuration tab). If the
Laminator is not detected and not manually checked, the tab is active; however, all functions
are grayed out.
• Calibrate button: Sends calibrate Laminator command to Printer. Follow the instruction
on the page for setting up the Printer.
• Help button: Launches help specific to this tab.
Step
Procedure
1
Select the Calibrate Laminator tab.
a. Ensure that the Cartridges are out of the Laminator.
b. Ensure the Laminator Cover is closed.
c. Click on the Calibrate button. (Note: The Printer's LCD will display
CALIBRATE PASSED. Error Message Calibration Failed may be solved
by manually increasing the sensor calibration number to 13 of higher
under the Advanced Settings tab. Do not use the AUTO calibrate
function)
d. Click on the OK button on the LCD display to complete the procedure.
HDP5000 High Definition Card Printer/Encoder User Guide (Rev. 1.3)
Fargo Electronics, Inc.
9-7