Connection method
-
SNMP community name
Note
When changing LAN switch settings as follows due to a configuration change, delete the registered LAN switch blade and register it again.
-
When changing from VCS to another mode, or vice versa
-
When changing a VCS ID or RBridge ID
Complete the changes to the settings on the target LAN switch before performing this procedure.
Use the following procedure to change LAN switch settings:
1.
In the ROR console server resource tree or network resource device tree, right-click the target LAN switch name and select [Modify]-
[Registration Settings] from the popup menu.
The [Modify LAN Switch] dialog is displayed.
2.
Make changes to the values as needed.
3.
Click <OK>.
The settings for the LAN switch are changed with the entered information.
Note
-
It is possible to set the IP address of the target switch to another unregistered LAN switch. However, this will result in the Resource
Orchestrator configuration being inconsistent with the actual network configuration.
If the IP address of the target switch is set to the same address as that of another unregistered LAN switch unintentionally, change
back the target LAN switch IP address to its original value according to the instructions given in this section.
If there are more than one LAN switch with inconsistent IP address configurations, delete all registered LAN switches according to
"9.4.2 Deleting LAN Switches and Network
LAN
Switches".
-
SSH connection (SSH version 2) can be selected for the following LAN switch blades.
-
LAN switch blade PY CB Eth Switch/IBP 10Gb 18/8 (1.00 or later version)
-
LAN switch blade PY CB Eth Switch/IBP 1Gb 36/8+2 (4.16 or later version)
-
LAN switch blade PY CB Eth Switch/IBP 1Gb 36/12 (3.12 or later version)
-
LAN switch blade PY CB Eth Switch/IBP 1Gb 18/6 (3.12 or later version)
-
LAN switch blade PY CB DCB SW 10Gb 18/6/6 (2.1.1_fuj or later version)
7.4.2 Changing VLANs Set for External Connection Ports of LAN Switch
Blades
VLAN types and IDs set on the external connection ports of a managed LAN switch blade can be changed.
Note
-
VLANs cannot be changed on PRIMERGY BX900/BX400 LAN switch blades operating in IBP mode.
-
If the port VLAN ID is unspecified or 1, a tagged VLAN ID cannot be set to 1.