Voltage related system shutdown

Message
System shutoff due to "X" current over
max value (level-critical; system drawing
too much current on voltage "X" bus)
System shutoff due to "X" V over voltage
(level-critical; system shutoff due to "X"
supply over voltage)
System shutoff due to "X" V under
voltage (level-critical system shutoff due to
"X" supply under voltage)
System shutoff due to VRM "X" over
voltage
System shutoff due to excessive (< 240
VA) loading

Temperature related system shutdown

Message
System shutoff due to board over
temperature (level-critical; board is over
temperature)
System shutoff due to CPU "X" over
temperature (level-critical; CPU "X" is over
temperature)
System shutoff due to CPU "X" under
temperature (level-critical; CPU "X" is under
temperature)
System shutoff due to DASD temperature
(sensor X) (level-critical; DASD area
reported temperature outside recommended
operating range)
System shutoff due to high ambient
temperature (level-critical; high ambient
temperature)
System shutoff due to system board
under temperature (level-critical; system
board is under temperature)

DASD checkout

Message
Hard drive "X" removal detected
(level-critical; hard drive "X" has been
removed)
Action
1. See "Power checkout" on page 19.
1. Check power supply connectors
2. Replace power supply
3. Replace power backplane
1. Check power supply connectors
2. Replace power supply
3. Replace power backplane
1. Replace VRM "X"
1. See "Power checkout" on page 19.
2. Cycle AC On/Off to enable retry
Action
1. Ensure system is being properly cooled, see "System reliability
considerations" on page 41.
2. Replace board
1. Ensure system is being properly cooled, see "System reliability
considerations" on page 41.
2. Replace CPU "X"
1. Ambient temperature must be within normal operating
specifications, see "Features and specifications" on page 3.
2.
1. Ensure system is being properly cooled, see "System reliability
considerations" on page 41.
1. Ambient temperature must be within normal operating
specifications, see "Features and specifications" on page 3.
1. Ambient temperature must be within normal operating
specifications, see "Features and specifications" on page 3.
Action
1. Information only, take action as appropriate.
101
Symptom-to-FRU index