Power Error Messages; System Shutdown; Voltage-Related System Shutdown - IBM IntelliStation Z Pro 6223 Hardware Maintenance Manual And Troubleshooting Manual

Hide thumbs Also See for IntelliStation Z Pro 6223:
Table of Contents

Advertisement

Power error messages

Note: See "System replaceable units" on page 117 to determine which components should be replaced by a field
service technician.
Message
Power supply x current share fault
(level-critical; excessive current demand on
power supply x)
Power supply x DC good fault
(level-critical; power good signal not detected
for power supply x)
Power supply x temperature fault
Power supply x removed
Power supply x fan fault (level-critical; fan
fault in power supply x)
Power supply x 12 V fault (level-critical;
overcurrent condition detected)
Power supply x 3.3 V fault (level-critical;
3.3 V power supply x had an error)
Power supply x 5 V fault (level-critical; 5 V
power supply x had an error)
System running non-redundant power
(level-noncritical; system does not have
redundant power)
System under recommended voltage for x
(level-warning; indicated voltage supply
under nominal value; value for x can be +12,
-12, or +5)

System shutdown

See the following tables when experiencing system shutdown related to voltage or
temperature problems.

Voltage-related system shutdown

Note: See "System replaceable units" on page 117 to determine which components should be replaced by a field
service technician.
Message
System shutoff due to x current over
max value (level-critical; system drawing
too much current on voltage x bus)
System shutoff due to x V over voltage
(level-critical; system shutoff due to x
supply over voltage)
110
IntelliStation Z Pro Types 6223 and 6227: Hardware Maintenance Manual and Troubleshooting Guide
Action
v Replace power supply x.
v Replace power supply x.
v Replace power supply x.
v No action required – information only.
v Replace power supply x.
v See "Power checkout" on page 22.
v See "Power checkout" on page 22.
v See "Power checkout" on page 22.
1. Add another power supply.
2. Remove options from system.
3. System can continue to operate without redundancy protection if
steps1 and 2 are not followed.
1. Check connections to the power subsystem.
2. Power supply.
3. Power cage assembly, if installed.
Action
v See "Power checkout" on page 22.
1. Check the power-supply connectors.
2. Power supply.
3. Power cage assembly, if installed.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intellistation z pro 6227

Table of Contents