Error Code/Symptom
1600 (The System Management
Processor is not functioning) Do the
following before replacing a FRU:
1. Ensure that a jumper is not installed
on J45.
2. Remove the ac power to the system,
wait 20 seconds; then, re-connect the
ac power. Wait 30 seconds; then,
power-on the system.
1601 (The system is able to communicate
to the System Management Processor, but
the System Management Processor failed
to respond at the start of POST.) Do the
following before replacing a FRU:
1. Remove the ac power to the system,
wait 20 seconds; then, re-connect the
ac power. Wait 30 seconds; then,
power-on the system.
2. Flash update the Service Processor.
1762 (Fixed Disk Configuration error)
178X (Fixed Disk error)
1800 (No more hardware interrupt
available for PCI adapter)
1962 (Drive does not contain a valid boot
sector)
2400 (Video controller test failure)
2462 (Video memory configuration error)
96
Hardware Maintenance Manual: xSeries 342 Type 8669
FRU/Action
1. System Board
1. Remote Supervisor Adapter, if installed
2. System Board
1. Fixed Disk Drive
2. Fixed Disk Cables
3. Run Configuration/Setup
4. Fixed Disk Adapter
5. SCSI Backplane
6. System Board
1. Fixed Disk Cables
2. Run Diagnostics
3. Fixed Disk Adapter
4. Fixed Disk Drive
5. System Board
1. Run Configuration/Setup
2. Failing Adapter
3. System Board
1. Verify a bootable operating system is installed.
2. Run Diagnostics
3. Hard Disk Drive
4. SCSI Backplane
5. Cable
6. System Board
1. Video Adapter (if installed)
2. System Board
1. Video Adapter (if installed)
2. System Board