Removing A Hard Disk Drive (Sr1530Sh); Figure 33. Removing Drive Carrier From The Server System (Sr1530Sh) - Intel SR1530HSH - Server System - 0 MB RAM User Manual

Server system
Table of Contents

Advertisement

17. Install the server system cover. For instructions, see
Cover".

Removing a Hard Disk Drive (SR1530SH)

1. Observe the safety and ESD precautions at the beginning of this book. See
Information" on page
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see
System Cover" on page
4. Disconnect the power and data cables from the drive.
5. HDD1 location only: Slide the power cable from the cable clip located on the top of
the hard drive carrier.
6. Remove the screw that holds the hard drive bracket to the chassis. See letter "A" in
Figure 33. Save this screw. You will use it to reinstall the drive assembly later.
7. Lift the drive carrier from the chassis. See letter "B" in Figure 33.

Figure 33. Removing Drive Carrier from the Server System (SR1530SH)

8. Remove the four screws that attach the hard drive to the drive carrier. Lift the drive
from the carrier. Store the drive in an anti-static bag.
9. If you are installing a new drive, skip the rest of these steps and instead see
"Installing a Hard Disk Drive (SR1530SH)" on page
10. Insert the screws that held the drive in the carrier into the screw locations on the
carrier for future use.
®
Intel
Server System SR1530SH/SR1530HSH User's Guide
iii.
24.
B
A
"Installing the Server System
"Removing the Server
AF001050
37, beginning with step 8.
"Safety
41