Power Error Messages - IBM 8832L1X Maintenance And Troubleshooting Manual

Server compute blade
Table of Contents

Advertisement

Power error messages

NOTE
See "System" on page 130 to determine which components should be replaced by a field
service technician.
Message
BSE +12V over recommended voltage
BSE +12V under recommended
voltage
BSE +5V over recommended voltage
BSE +5V under recommended voltage
BSE +18V over recommended voltage
BSE +18V under recommended
voltage
BSE +3.3V over recommended voltage
BSE +3.3V under recommended
voltage
BSE +2.5V over recommended voltage
BSE +2.5V under recommended
voltage
BSE +1.8V over recommended voltage
BSE +1.8V under recommended
voltage
System Power Good fault
1. Check SBCE power (see the
SBCE: Hardware Maintenance Manual and Troubleshooting
®
Guide on the Intel
Blade Server Chassis SBCE Resource
for details).
CD
2.
Reseat blade storage expansion option.
3.
Replace blade storage expansion option.
1. Reseat blade storage expansion option.
2.
Replace blade storage expansion option.
1. Reseat blade storage expansion option.
2.
Replace blade storage expansion option.
1. Reseat blade storage expansion option.
2.
Replace blade storage expansion option.
1. Reseat blade storage expansion option.
2.
Replace blade storage expansion option.
1. Reseat blade storage expansion option.
2.
Replace blade storage expansion option.
1. Reseat blade storage expansion option.
2.
Replace blade storage expansion option.
1. Reseat blade storage expansion option.
2.
Replace blade storage expansion option.
1. Reseat blade storage expansion option.
2.
Replace blade storage expansion option.
1. Reseat blade storage expansion option.
2.
Replace blade storage expansion option.
1. Reseat blade storage expansion option.
2.
Replace blade storage expansion option.
1. Reseat blade storage expansion option.
2.
Replace blade storage expansion option.
1. Check SBCE power (see the
SBCE: Hardware Maintenance Manual and Troubleshooting
®
Guide on the Intel
Blade Server Chassis SBCE Resource
for details).
CD
2.
Reseat blade server.
3.
Replace blade server.
Action
®
Intel
Blade Server Chassis
®
Intel
Blade Server Chassis
123

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sbx82

Table of Contents