Temperature-related system shutdown
NOTE
See "System" on page 130 to determine which components should be replaced by a field
service technician.
Message
System shutoff due to CPU x over
temperature
System shutoff due to Blade Storage
Expansion option temperature
CPU x shut off due to over
temperature
Critical Blower Failure, blade server
powering down
Power Modules are over temperature,
blade server powering down
DASD checkout
NOTE
See "System" on page 130 to determine which components should be replaced by a field
service technician.
Message
Hard drive x removal detected (level-
critical; hard drive x has been removed)
Undetermined problems
NOTE
When troubleshooting a problem with the Intel Server Compute Blade SBX82, it must be
determined whether the problem is a blade server problem or a problem with the SBCE unit.
•
If the SBCE unit contains more than one blade server and only one of the blade servers exhibits the
problem, it is likely that it is a blade server problem.
126
1. Ensure that the system is being properly cooled; see
"System reliability considerations" on page 17.
2.
Replace microprocessor x.
1. Ensure that the system is being properly cooled; see
"System reliability considerations" on page 17.
2.
Replace Blade Storage Expansion option.
1. Ensure that the system is being properly cooled; see
"System reliability considerations" on page 17.
2.
Replace microprocessor x.
•
See the
Intel
Maintenance Manual and Troubleshooting Guide on the
®
Intel
Blade Server Chassis SBCE Resource CD
•
See the Intel
Maintenance Manual and Troubleshooting Guide on the
®
Intel
Blade Server Chassis SBCE Resource CD.
•
Information only, take action as appropriate.
Intel® Server Compute Blade SBX82: Hardware Maintenance Manual and Troubleshooting Guide
Action
®
Blade Server Chassis SBCE: Hardware
®
Blade Server Chassis SBCE: Hardware
Action
.